Xpower X-8/X-12 Professional Axial Air Mover Owner's Manual - Manuals+ (2022)

Contents hide

1Xpower X-8/X-12 Professional Axial Air Mover Owner’s Manual

2Introduction

3Features:

4Safety Instructions

4.1DANGER!

5Maintenance Instructions

6Troubleshooting

8XPOWER Limited Warranty (USA)

9XPOWER’s

10Service

11Parts List

12Specifications

13XPOWER Limited Warranty (USA)

14Important!

15Service

16Parts List

17Accessories

19DUCTING HOSE CARRIER

20Warranty Registration (for US user only)

22Documents / Resources

22.1Related Manuals / Resources

Xpower X-8/X-12 Professional Axial Air Mover Owner’s Manual
Xpower X-8/X-12 Professional Axial Air Mover Owner's Manual - Manuals+ (2)

Introduction

XPOWER Axial Air Movers are ETL/CETL certified and offer complete control of air velocity and volume. Designed with efficiency and flexibility of use in mind, both the X-8 and X-12 feature alow amp draw and a powerful sealed motor to circulate air efficiently and effectively. The X-8 and X-12 function to deliver dry air to ventilate, create negative air pressure or simply to help complete any drying process for a variety of surfaces. Optional duct hoses offer the flexibility to ventilate narrow spaces up to 125 ft. Visit www.xpower.ws to order additional parts and adapters.

Features:

  • Low power draw with 1000CFM (X-8) & 2500CFM (X-12) when switched on high
  • Super Quiet and Lightweight
  • Variable Speed Control Switch
  • Durable ABS Plastic Housing
  • 20’ Power Cord
  • Dual Thermal Protection

Safety Instructions

DANGER!
  • Always refer to OSHA and industry standards when determining how to use unit for ventilation purposes.
  • Avoid entering any confined area that has not yet been tested and proven safe for work personnel.
  1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit with wet hands or while standing in water.
  2. To avoid risk of injury, do not direct air flow at face or body.
  3. Suitable for use with solid-state speed controls.
  4. Use only with GFCI protected receptacles. Please contact a qualified electrician for verification and / or installation of a GFCI receptacle if necessary.
  5. Do not operate any unit with a damaged cord or plug. Discard axial air mover or return to an authorized service facility for examination and/or repair.
  6. This is an automatically operated device. To reduce the risk of injury disconnect from power supply before servicing.
  7. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
  8. Do not allow children to play with or around an axial air mover at any time.
  9. Do not move or carry the axial air mover while unit is operating.
  10. Keep air intakes and exhausts clean at all times to avoid clogging or blocking in order to prevent overheating the unit. Blocking the air intake could result in a fire or electrical hazards.
  11. To prevent injury to persons and to avoid objects from coming in contact with the fan blade, do not remove any screens or safety guards from this unit. Damage in this manner will void your warranty.
  12. Always place the axial air mover on a smooth and level surface for safe operation.
  13. Do not use unit if defective or damaged.
  14. Unplug the unit before performing any maintenance, cleaning, or servicing.
  15. Any misuse or abuse of this product will void the warranty.
  16. An electronic instruction manual can be obtained through www.xpower.ws

Maintenance Instructions

  1. To keep the unit clean, use a damp cloth to wipe the surface of the housing.
  2. Never clean the Axial Air Mover directly with water.
  3. When not in use, unplug and store the unit in a dry indoor place out of reach of children.
  4. Always disconnect from its power source before performing any maintenance or cleaning.

Troubleshooting

SYMPTOMPROBABLE CAUSEACTION

Motor Not Running

Switched Off

Make sure unit is plugged in and switch is turned to ON position.
Power failureCheck outlet/Change to another outlet
Wiring failureContact XPOWER for repair

Scraping Noise From Fan

Obstructions at the intake or exhaust of fanRemove obstruction(s)
Fan brokenContact XPOWER for repair
Weak Air FlowObstructed vents/inletsUnplug unit to clean vents and inlets

Specifications

ModelX-8X-12
Power1/3 HP 115V1/2 HP 115V
Amp2.5A4.5A
Rated Airflow (High)1000CFM2500CFM
SpeedsVariableVariable
RPM1,100 / 3,3001,100 / 3,300
Cord20′ / 18AWG20′ / 18AWG
Overheating ProtectionDual Thermal ProtectionDual Thermal Protection
Weight13.4 lbs23.4 lbs
Size(inches) (L x W xH)13.6 x 11.1 x 15.4 inch.15 x 13.6 x 18 inch.
HousingABSABS
SafetyETL / C-ETLETL / C-ETL

XPOWER Limited Warranty (USA)

XPOWER’s Limited Warranty covers the unit (excludes POWER CORD) from defects in material and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.

XPOWER’s

Limited Warranty covers the unit (excludes POWER CORD) from defects in material and craftsmanship. The Warranty covers normal use for a term of one year from the original date of purchase including parts, labor and one way shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.

Service

For Warranty service and parts replacement (US users only), you must:

  1. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorization)
  2. Have original proof of
  3. Use the original undamaged packaging or an industrial certified packaging

End user will be responsible to ship the unit (with RMA Number showing on the shipping label) to the XPOWER Service Department. XPOWER to inspect, assess and advise the repairs needed and the applicable cost, if any. For users outside the US, please contact XPOWER Distributor in your country or region for Warranty service and parts replacement.

Parts List

Item No.Parts NameItem No.Parts Name
1Air Inlet / Outlet2Motor
3Handle Cover4Speed Switch
5Housing6Fan
7Power Cord8Capacitor
9Power Cord Panel10Label Panel

Repairs: Any internal repairs should be performed by a qualified technician. Call your local
distributor or contact our Service Department at 626-285-3301.

Specifications

ModelX-8X-12
Power1/3 HP 115V1/2 HP 115V
Amp2.5A4.5A
Rated Airflow (High)1000CFM2500CFM
SpeedsVariableVariable
RPM1,100 / 3,3001,100 / 3,300
Cord20′ / 18AWG20′ / 18AWG
Overheating ProtectionDual Thermal ProtectionDual Thermal Protection
Weight13.4 lbs23.4 lbs
Size(inches) (L x W xH)13.6 x 11.1 x 15.4 inch.15 x 13.6 x 18 inch.
HousingABSABS
SafetyETL / C-ETLETL / C-ETL

XPOWER Limited Warranty (USA)

XPOWER’s Limited Warranty covers the unit (excludes POWER CORD) from defects in material and craftsmanship. The Warranty covers normal use for a term of one year from the original date
of purchase including parts, labor and one way shipping. Non-contiguous states must pay for roundtrip freight. A purchase receipt must be provided.

Important!

This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse, disassembly, alteration, corrosive chemicals, improper voltage, fire, flood, negligence, accident, improperly or incorrectly performed maintenance or repair, or failure to perform necessary maintenance or repair, or if the use of this product is not in compliance with the instructions and specifications for its use.

Service

For Warranty service and parts replacement (US users only), you must:
A. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorization) number.
B. Have original proof of purchase.
C. Use the original undamaged packaging or an industrial certified packaging method. End user will be responsible to ship the unit (with RMA Number showing on the shipping label) to the XPOWER Service Department. XPOWER to inspect, assess and advise the repairs needed and the applicable cost, if any. For users outside the US, please contact XPOWER Distributor in your country or region for Warranty service and parts replacement.

Parts List

Item No.Parts NameItem No.Parts Name
1Air Inlet / Outlet2Motor
3Handle Cover4Speed Switch
5Housing6Fan
7Power Cord8Capacitor
9Power Cord Panel10Label Panel

Xpower X-8/X-12 Professional Axial Air Mover Owner's Manual - Manuals+ (3)

Accessories

Ducting Hose items listed below are available for purchase via www.xpower.ws. Hoses can extend air flow up to 125ft. Keep in mind that as the ducting hose length increases, the air flow rate will decrease.

Xpower X-8/X-12 Professional Axial Air Mover Owner's Manual - Manuals+ (4)

DUCTING HOSE

Item#DiameterLength
XPOWER 8DH258”25’
XPOWER 12DH2512”25’

DUCTING HOSE CARRIER

XPOWER 8DHC (compatible with 8DH25)

Xpower X-8/X-12 Professional Axial Air Mover Owner's Manual - Manuals+ (5)

Warranty Registration (for US user only)

For your product warranty, please complete and mail / fax this form to XPOWER MANUFACTURE, INC.
Address: 220 Clary Ave., San Gabriel, CA 91776. Tel: 626-285-3301 Fax: 626-285-3302 (For your convenience, register your product online at xpower.ws)

Read More About This Manual & Download PDF:

Documents / Resources

Xpower X-8/X-12 Professional Axial Air Mover [pdf] Owner's Manual
X-8, X-12, Professional Axial Air Mover, X-8 Professional Axial Air Mover, X-12 Professional Axial Air Mover

Related Manuals / Resources

Top Articles

Latest Posts

Article information

Author: Carmelo Roob

Last Updated: 10/13/2022

Views: 6596

Rating: 4.4 / 5 (65 voted)

Reviews: 80% of readers found this page helpful

Author information

Name: Carmelo Roob

Birthday: 1995-01-09

Address: Apt. 915 481 Sipes Cliff, New Gonzalobury, CO 80176

Phone: +6773780339780

Job: Sales Executive

Hobby: Gaming, Jogging, Rugby, Video gaming, Handball, Ice skating, Web surfing

Introduction: My name is Carmelo Roob, I am a modern, handsome, delightful, comfortable, attractive, vast, good person who loves writing and wants to share my knowledge and understanding with you.